SV, SVO, SVOO, SJ, SJO, SJOO, SJOW, SJOOW, S, SO, SOO, SOW, SOOW

Properties

Conductor: annealed bare stranded copper wires.

Insulation: EPR Rubber

Sheath: CPE Rubber

Standard: UL62, CSA22.2

SV, SVO, SVOO Specification

SpecificationConductor
(no./mm)
Insulation Thickness
(mm)
Insulation Diameter
(mm)
Sheath Thickness
(mm)
Overall Diameter
(mm)
18AWGx2C41/0.160.382.150.766.05
17AWGx2C52/0.160.382.300.766.35
16AWGx2C26/0.2540.382.450.766.65
18AWGx3C41/0.160.382.150.766.35
17AWGx3C52/0.160.382.300.766.70
16AWGx3C26/0.2540.382.450.767.00

SJ, SJO, SJOW, SJOO, SJOOW Specification

SpecificationConductor
(no./mm)
Insulation Thickness
(mm)
Insulation Diameter
(mm)
Sheath Thickness
(mm)
Overall Diameter
(mm)
18AWGx2C41/0.160.762.800.767.35
16AWGx2C26/0.2540.763.100.767.95
14AWGx2C41/0.2540.763.500.768.70
12AWGx2C65/0.2540.764.001.1410.50
18AWGx3C41/0.160.762.800.767.80
16AWGx3C26/0.2540.763.100.768.40
14AWGx3C41/0.2540.763.500.769.30
12AWGx3C65/0.2540.764.001.1411.00
18AWGx4C41/0.160.762.800.768.60
16AWGx4C26/0.2540.763.100.769.20
14AWGx4C41/0.2540.763.500.7610.30
12AWGx4C65/0.2540.764.001.1412.10
18AWGx5C41/0.160.762.800.769.30
16AWGx5C26/0.2540.763.100.7610.10
14AWGx5C41/0.2540.763.500.7611.10
12AWGx5C65/0.2540.764.001.1413.25

S, SO, SOO, SOW, SOOW Specification

SpecificationConductor
(no./mm)
Insulation Thickness
(mm)
Insulation Diameter
(mm)
Sheath Thickness
(mm)
Overall Diameter
(mm)
18AWGx2C41/0.160.762.801.528.80
16AWGx2C26/0.2540.763.101.529.45
14AWGx2C41/0.2541.144.302.0312.80
12AWGx2C65/0.2541.144.652.4114.12
18AWGx3C41/0.160.762.801.529.30
16AWGx3C26/0.2540.763.101.529.95
14AWGx3C41/0.2541.144.302.0313.50
12AWGx3C65/0.2541.144.652.4115.35
18AWGx4C41/0.160.762.801.529.95
16AWGx4C26/0.2540.763.101.5210.70
14AWGx4C41/0.2541.144.302.0314.70
12AWGx4C65/0.2541.144.652.4116.61

Part Name Interpretation

S = Service Cord

J = Junior Service, 300V

V = Vacuum, typically used with vacuum cleaners and other portable cleaning devices.

O = Oil resistant outer jacket.

OO = Oil resistant outer jacket and Oil resistant insulation.

W = Weather and water resistant, approved for indoor and outdoor use.